Deoxygenation Constant given Organic Matter Present at Start of BOD Solution

STEP 0: Pre-Calculation Summary
Formula Used
Deoxygenation Constant = -(1/Time in days)*log10(Oxygen Equivalent/Organic Matter at Start)
KD = -(1/t)*log10(Lt/L)
This formula uses 1 Functions, 4 Variables
Functions Used
log10 - The common logarithm, also known as the base-10 logarithm or the decimal logarithm, is a mathematical function that is the inverse of the exponential function., log10(Number)
Variables Used
Deoxygenation Constant - (Measured in 1 Per Second) - Deoxygenation Constant is the value obtained after decomposing of oxygen in sewage.
Time in days - (Measured in Second) - Time in days is the time calculated in days.
Oxygen Equivalent - (Measured in Kilogram per Cubic Meter) - Oxygen Equivalent is the oxidisable organic matter present in sewage.
Organic Matter at Start - (Measured in Kilogram per Cubic Meter) - Organic Matter at Start is the total organic matter present in the sewage at the start of the BOD reaction.
STEP 1: Convert Input(s) to Base Unit
Time in days: 10 Day --> 864000 Second (Check conversion ​here)
Oxygen Equivalent: 0.21 Milligram per Liter --> 0.00021 Kilogram per Cubic Meter (Check conversion ​here)
Organic Matter at Start: 40 Milligram per Liter --> 0.04 Kilogram per Cubic Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
KD = -(1/t)*log10(Lt/L) --> -(1/864000)*log10(0.00021/0.04)
Evaluating ... ...
KD = 2.63870450994681E-06
STEP 3: Convert Result to Output's Unit
2.63870450994681E-06 1 Per Second -->0.227984069659404 1 Per Day (Check conversion ​here)
FINAL ANSWER
0.227984069659404 0.227984 1 Per Day <-- Deoxygenation Constant
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 600+ more calculators!

6 Deoxygenation Constant Calculators

Deoxygenation Constant given Total Amount of Organic Matter Oxidised
​ Go Deoxygenation Constant = -(1/Time in days)*log10(1-(Organic Matter Oxidised/Organic Matter at Start))
Deoxygenation Constant given Organic Matter Present at Start of BOD
​ Go Deoxygenation Constant = -(1/Time in days)*log10(Oxygen Equivalent/Organic Matter at Start)
Deoxygenation Constant at given Temperature
​ Go Deoxygenation Constant at Temperature T = Deoxygenation Constant at Temperature 20*(1.047)^(Temperature-20)
Deoxygenation Constant at 20 degree Celsius
​ Go Deoxygenation Constant at Temperature 20 = Deoxygenation Constant at Temperature T/(1.047^(Temperature-20))
De-oxygenation Constant
​ Go Deoxygenation Constant = 0.434*Rate Constant in BOD
Deoxygenation Constant
​ Go Deoxygenation Constant = Rate Constant in BOD/2.3

Deoxygenation Constant given Organic Matter Present at Start of BOD Formula

Deoxygenation Constant = -(1/Time in days)*log10(Oxygen Equivalent/Organic Matter at Start)
KD = -(1/t)*log10(Lt/L)

What is BOD?

BOD is a measure of the amount of oxygen required to remove waste organic matter from water in the process of decomposition by aerobic bacteria.

How to Calculate Deoxygenation Constant given Organic Matter Present at Start of BOD?

Deoxygenation Constant given Organic Matter Present at Start of BOD calculator uses Deoxygenation Constant = -(1/Time in days)*log10(Oxygen Equivalent/Organic Matter at Start) to calculate the Deoxygenation Constant, The Deoxygenation Constant given Organic Matter Present at Start of BOD is defined as the BOD rate constant at base 10. Deoxygenation Constant is denoted by KD symbol.

How to calculate Deoxygenation Constant given Organic Matter Present at Start of BOD using this online calculator? To use this online calculator for Deoxygenation Constant given Organic Matter Present at Start of BOD, enter Time in days (t), Oxygen Equivalent (Lt) & Organic Matter at Start (L) and hit the calculate button. Here is how the Deoxygenation Constant given Organic Matter Present at Start of BOD calculation can be explained with given input values -> 19697.82 = -(1/864000)*log10(0.00021/0.04).

FAQ

What is Deoxygenation Constant given Organic Matter Present at Start of BOD?
The Deoxygenation Constant given Organic Matter Present at Start of BOD is defined as the BOD rate constant at base 10 and is represented as KD = -(1/t)*log10(Lt/L) or Deoxygenation Constant = -(1/Time in days)*log10(Oxygen Equivalent/Organic Matter at Start). Time in days is the time calculated in days, Oxygen Equivalent is the oxidisable organic matter present in sewage & Organic Matter at Start is the total organic matter present in the sewage at the start of the BOD reaction.
How to calculate Deoxygenation Constant given Organic Matter Present at Start of BOD?
The Deoxygenation Constant given Organic Matter Present at Start of BOD is defined as the BOD rate constant at base 10 is calculated using Deoxygenation Constant = -(1/Time in days)*log10(Oxygen Equivalent/Organic Matter at Start). To calculate Deoxygenation Constant given Organic Matter Present at Start of BOD, you need Time in days (t), Oxygen Equivalent (Lt) & Organic Matter at Start (L). With our tool, you need to enter the respective value for Time in days, Oxygen Equivalent & Organic Matter at Start and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Deoxygenation Constant?
In this formula, Deoxygenation Constant uses Time in days, Oxygen Equivalent & Organic Matter at Start. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Deoxygenation Constant = 0.434*Rate Constant in BOD
  • Deoxygenation Constant = -(1/Time in days)*log10(1-(Organic Matter Oxidised/Organic Matter at Start))
  • Deoxygenation Constant = Rate Constant in BOD/2.3
Let Others Know