Deoxygenation Constant given Total Amount of Organic Matter Oxidised Solution

STEP 0: Pre-Calculation Summary
Formula Used
Deoxygenation Constant = -(1/Time in days)*log10(1-(Organic Matter Oxidised/Organic Matter at Start))
KD = -(1/t)*log10(1-(Yt/L))
This formula uses 1 Functions, 4 Variables
Functions Used
log10 - The common logarithm, also known as the base-10 logarithm or the decimal logarithm, is a mathematical function that is the inverse of the exponential function., log10(Number)
Variables Used
Deoxygenation Constant - (Measured in 1 Per Second) - Deoxygenation Constant is the value obtained after decomposing of oxygen in sewage.
Time in days - (Measured in Second) - Time in days is the time calculated in days.
Organic Matter Oxidised - (Measured in Milligram per Liter) - Organic Matter Oxidised is the total amount of organic matter which is oxidised during the BOD reaction.
Organic Matter at Start - (Measured in Milligram per Liter) - Organic Matter at Start is the total organic matter present in the sewage at the start of the BOD reaction.
STEP 1: Convert Input(s) to Base Unit
Time in days: 10 Day --> 864000 Second (Check conversion ​here)
Organic Matter Oxidised: 0.4 Milligram per Liter --> 0.4 Milligram per Liter No Conversion Required
Organic Matter at Start: 40 Milligram per Liter --> 40 Milligram per Liter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
KD = -(1/t)*log10(1-(Yt/L)) --> -(1/864000)*log10(1-(0.4/40))
Evaluating ... ...
KD = 5.0518581046876E-09
STEP 3: Convert Result to Output's Unit
5.0518581046876E-09 1 Per Second -->0.000436480540245009 1 Per Day (Check conversion ​here)
FINAL ANSWER
0.000436480540245009 0.000436 1 Per Day <-- Deoxygenation Constant
(Calculation completed in 00.021 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 600+ more calculators!

6 Deoxygenation Constant Calculators

Deoxygenation Constant given Total Amount of Organic Matter Oxidised
​ Go Deoxygenation Constant = -(1/Time in days)*log10(1-(Organic Matter Oxidised/Organic Matter at Start))
Deoxygenation Constant given Organic Matter Present at Start of BOD
​ Go Deoxygenation Constant = -(1/Time in days)*log10(Oxygen Equivalent/Organic Matter at Start)
Deoxygenation Constant at given Temperature
​ Go Deoxygenation Constant at Temperature T = Deoxygenation Constant at Temperature 20*(1.047)^(Temperature-20)
Deoxygenation Constant at 20 degree Celsius
​ Go Deoxygenation Constant at Temperature 20 = Deoxygenation Constant at Temperature T/(1.047^(Temperature-20))
De-oxygenation Constant
​ Go Deoxygenation Constant = 0.434*Rate Constant in BOD
Deoxygenation Constant
​ Go Deoxygenation Constant = Rate Constant in BOD/2.3

Deoxygenation Constant given Total Amount of Organic Matter Oxidised Formula

Deoxygenation Constant = -(1/Time in days)*log10(1-(Organic Matter Oxidised/Organic Matter at Start))
KD = -(1/t)*log10(1-(Yt/L))

What is Total Amount of Organic Matter Oxidised?

The Total amount of organic matter oxidised is the total organic matter which is utilized in the BOD reaction.

How to Calculate Deoxygenation Constant given Total Amount of Organic Matter Oxidised?

Deoxygenation Constant given Total Amount of Organic Matter Oxidised calculator uses Deoxygenation Constant = -(1/Time in days)*log10(1-(Organic Matter Oxidised/Organic Matter at Start)) to calculate the Deoxygenation Constant, The Deoxygenation Constant given Total Amount of Organic Matter Oxidised is defined as the BOD rate constant on base 10 at a given temperature. Deoxygenation Constant is denoted by KD symbol.

How to calculate Deoxygenation Constant given Total Amount of Organic Matter Oxidised using this online calculator? To use this online calculator for Deoxygenation Constant given Total Amount of Organic Matter Oxidised, enter Time in days (t), Organic Matter Oxidised (Yt) & Organic Matter at Start (L) and hit the calculate button. Here is how the Deoxygenation Constant given Total Amount of Organic Matter Oxidised calculation can be explained with given input values -> 37.71192 = -(1/864000)*log10(1-(0.0004/0.04)).

FAQ

What is Deoxygenation Constant given Total Amount of Organic Matter Oxidised?
The Deoxygenation Constant given Total Amount of Organic Matter Oxidised is defined as the BOD rate constant on base 10 at a given temperature and is represented as KD = -(1/t)*log10(1-(Yt/L)) or Deoxygenation Constant = -(1/Time in days)*log10(1-(Organic Matter Oxidised/Organic Matter at Start)). Time in days is the time calculated in days, Organic Matter Oxidised is the total amount of organic matter which is oxidised during the BOD reaction & Organic Matter at Start is the total organic matter present in the sewage at the start of the BOD reaction.
How to calculate Deoxygenation Constant given Total Amount of Organic Matter Oxidised?
The Deoxygenation Constant given Total Amount of Organic Matter Oxidised is defined as the BOD rate constant on base 10 at a given temperature is calculated using Deoxygenation Constant = -(1/Time in days)*log10(1-(Organic Matter Oxidised/Organic Matter at Start)). To calculate Deoxygenation Constant given Total Amount of Organic Matter Oxidised, you need Time in days (t), Organic Matter Oxidised (Yt) & Organic Matter at Start (L). With our tool, you need to enter the respective value for Time in days, Organic Matter Oxidised & Organic Matter at Start and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Deoxygenation Constant?
In this formula, Deoxygenation Constant uses Time in days, Organic Matter Oxidised & Organic Matter at Start. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Deoxygenation Constant = 0.434*Rate Constant in BOD
  • Deoxygenation Constant = -(1/Time in days)*log10(Oxygen Equivalent/Organic Matter at Start)
  • Deoxygenation Constant = Rate Constant in BOD/2.3