Depth of Water in Well given Discharge in Confined Aquifer with Base 10 Solution

STEP 0: Pre-Calculation Summary
Formula Used
Depth of Water in Well = Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Permeability*Aquifer Thickness During Pumping))
hwell = bw-((Q*log((Rw/r),10))/(2.72*Kw*bp))
This formula uses 1 Functions, 7 Variables
Functions Used
log - Logarithmic function is an inverse function to exponentiation., log(Base, Number)
Variables Used
Depth of Water in Well - (Measured in Meter) - Depth of Water in Well is measured above the impermeable layer.
Aquifer Thickness - (Measured in Meter) - Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the rate of flow of a liquid.
Radius of Influence - (Measured in Meter) - Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Radius of well - (Measured in Meter) - Radius of well is defined as the distance from center of well to its outer boundary.
Coefficient of Permeability - (Measured in Meter per Second) - Coefficient of Permeability is the velocity in meters or centimeters per second of water through soils.
Aquifer Thickness During Pumping - (Measured in Meter) - Aquifer Thickness During Pumping is the thickness of aquifer during pumping stage.
STEP 1: Convert Input(s) to Base Unit
Aquifer Thickness: 15 Meter --> 15 Meter No Conversion Required
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Radius of Influence: 8.6 Meter --> 8.6 Meter No Conversion Required
Radius of well: 7.5 Meter --> 7.5 Meter No Conversion Required
Coefficient of Permeability: 1000 Centimeter per Second --> 10 Meter per Second (Check conversion ​here)
Aquifer Thickness During Pumping: 2.36 Meter --> 2.36 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
hwell = bw-((Q*log((Rw/r),10))/(2.72*Kw*bp)) --> 15-((1.01*log((8.6/7.5),10))/(2.72*10*2.36))
Evaluating ... ...
hwell = 14.7352827678247
STEP 3: Convert Result to Output's Unit
14.7352827678247 Meter --> No Conversion Required
FINAL ANSWER
14.7352827678247 14.73528 Meter <-- Depth of Water in Well
(Calculation completed in 00.005 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

8 Depth of Water in Well Calculators

Depth of Water in Well given Discharge in Confined Aquifer
​ Go Depth of Water in Well = Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of well),e))/(2*pi*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping))
Depth of Water in 1st Well given Confined Aquifer Discharge
​ Go Depth of Water 1 = Depth of Water 2-((Discharge*log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))/(2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping))
Depth of Water in 2nd Well given Confined Aquifer Discharge
​ Go Depth of Water 2 = Depth of Water 1+((Discharge*log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))/(2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping))
Depth of Water in Well given Coefficient of Transmissibility
​ Go Depth of Water = Initial Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of well),e))/(2*pi*Coefficient of Transmissibility))
Depth of Water in Well given Discharge in Confined Aquifer with Base 10
​ Go Depth of Water in Well = Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Permeability*Aquifer Thickness During Pumping))
Depth of Water in 1st Well given Coefficient of Transmissibility
​ Go Depth of Water 1 = Depth of Water 2-((Discharge*log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))/(2.72*Coefficient of Transmissibility))
Depth of Water in 2nd Well given Coefficient of Transmissibility
​ Go Depth of Water 2 = Depth of Water 1+((Discharge*log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))/(2.72*Coefficient of Transmissibility))
Depth of Water in Well given Coefficient of Transmissibility with Base 10
​ Go Depth of Water in Well = Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Transmissibility))

Depth of Water in Well given Discharge in Confined Aquifer with Base 10 Formula

Depth of Water in Well = Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Permeability*Aquifer Thickness During Pumping))
hwell = bw-((Q*log((Rw/r),10))/(2.72*Kw*bp))

What is Aquifer?

An aquifer is an underground layer of water-bearing permeable rock, rock fractures or unconsolidated materials (gravel, sand, or silt). Groundwater can be extracted using a water well.

How to Calculate Depth of Water in Well given Discharge in Confined Aquifer with Base 10?

Depth of Water in Well given Discharge in Confined Aquifer with Base 10 calculator uses Depth of Water in Well = Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Permeability*Aquifer Thickness During Pumping)) to calculate the Depth of Water in Well, The Depth of Water in Well given Discharge in Confined Aquifer with Base 10 is defined as the value of depth of water in well when we have prior information of other parameters used. Depth of Water in Well is denoted by hwell symbol.

How to calculate Depth of Water in Well given Discharge in Confined Aquifer with Base 10 using this online calculator? To use this online calculator for Depth of Water in Well given Discharge in Confined Aquifer with Base 10, enter Aquifer Thickness (bw), Discharge (Q), Radius of Influence (Rw), Radius of well (r), Coefficient of Permeability (Kw) & Aquifer Thickness During Pumping (bp) and hit the calculate button. Here is how the Depth of Water in Well given Discharge in Confined Aquifer with Base 10 calculation can be explained with given input values -> 14.73528 = 15-((1.01*log((8.6/7.5),10))/(2.72*10*2.36)).

FAQ

What is Depth of Water in Well given Discharge in Confined Aquifer with Base 10?
The Depth of Water in Well given Discharge in Confined Aquifer with Base 10 is defined as the value of depth of water in well when we have prior information of other parameters used and is represented as hwell = bw-((Q*log((Rw/r),10))/(2.72*Kw*bp)) or Depth of Water in Well = Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Permeability*Aquifer Thickness During Pumping)). Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water, Discharge is the rate of flow of a liquid, Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table, Radius of well is defined as the distance from center of well to its outer boundary, Coefficient of Permeability is the velocity in meters or centimeters per second of water through soils & Aquifer Thickness During Pumping is the thickness of aquifer during pumping stage.
How to calculate Depth of Water in Well given Discharge in Confined Aquifer with Base 10?
The Depth of Water in Well given Discharge in Confined Aquifer with Base 10 is defined as the value of depth of water in well when we have prior information of other parameters used is calculated using Depth of Water in Well = Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Permeability*Aquifer Thickness During Pumping)). To calculate Depth of Water in Well given Discharge in Confined Aquifer with Base 10, you need Aquifer Thickness (bw), Discharge (Q), Radius of Influence (Rw), Radius of well (r), Coefficient of Permeability (Kw) & Aquifer Thickness During Pumping (bp). With our tool, you need to enter the respective value for Aquifer Thickness, Discharge, Radius of Influence, Radius of well, Coefficient of Permeability & Aquifer Thickness During Pumping and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Depth of Water in Well?
In this formula, Depth of Water in Well uses Aquifer Thickness, Discharge, Radius of Influence, Radius of well, Coefficient of Permeability & Aquifer Thickness During Pumping. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Depth of Water in Well = Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of well),e))/(2*pi*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping))
  • Depth of Water in Well = Aquifer Thickness-((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Transmissibility))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!