Dry Plate Pressure Drop in Distillation Column Design Solution

STEP 0: Pre-Calculation Summary
Formula Used
Dry Plate Head Loss = 51*((Vapor Velocity Based on Hole Area/Orifice Coefficient)^2)*(Vapor Density in Distillation/Liquid Density)
hd = 51*((Uh/Co)^2)*(ρV/ρL)
This formula uses 5 Variables
Variables Used
Dry Plate Head Loss - (Measured in Meter) - Dry Plate Head Loss is the loss in pressure due to vapor flow through the holes expressed in terms of head.
Vapor Velocity Based on Hole Area - (Measured in Meter per Second) - Vapor Velocity Based on Hole Area is defined as the actual vapor velocity on the basis of hole area available to the vapor passing through the column.
Orifice Coefficient - Orifice Coefficient is a constant that depends on plate thickness, hole diameter and the ratio of hole to perforated area.
Vapor Density in Distillation - (Measured in Kilogram per Cubic Meter) - Vapor Density in Distillation is defined as the ratio of mass to the volume of vapor at particular temperature in a distillation Column.
Liquid Density - (Measured in Kilogram per Cubic Meter) - Liquid Density is defined as the ratio of mass of given fluid with respect to the volume that it occupies.
STEP 1: Convert Input(s) to Base Unit
Vapor Velocity Based on Hole Area: 20.2585 Meter per Second --> 20.2585 Meter per Second No Conversion Required
Orifice Coefficient: 0.83 --> No Conversion Required
Vapor Density in Distillation: 1.71 Kilogram per Cubic Meter --> 1.71 Kilogram per Cubic Meter No Conversion Required
Liquid Density: 995 Kilogram per Cubic Meter --> 995 Kilogram per Cubic Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
hd = 51*((Uh/Co)^2)*(ρVL) --> 51*((20.2585/0.83)^2)*(1.71/995)
Evaluating ... ...
hd = 52.21575867204
STEP 3: Convert Result to Output's Unit
52.21575867204 Meter --> No Conversion Required
FINAL ANSWER
52.21575867204 52.21576 Meter <-- Dry Plate Head Loss
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rishi Vadodaria
Malviya National Institute Of Technology (MNIT JAIPUR ), JAIPUR
Rishi Vadodaria has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Vaibhav Mishra
DJ Sanghvi College of Engineering (DJSCE), Mumbai
Vaibhav Mishra has verified this Calculator and 200+ more calculators!

25 Distillation Tower Design Calculators

Relative Volatility of Two Components Based on Normal Boiling Point and Latent Heat of Vaporization
​ Go Relative Volatility = exp(0.25164*((1/Normal Boiling Point of Component 1)-(1/Normal Boiling Point of Component 2))*(Latent Heat of Vaporization of Component 1+Latent Heat of Vaporization of Component 2))
Maximum Allowable Vapor Velocity given Plate Spacing and Fluid Densities
​ Go Maximum Allowable Vapor Velocity = (-0.171*(Plate Spacing)^2+0.27*Plate Spacing-0.047)*((Liquid Density-Vapor Density in Distillation)/Vapor Density in Distillation)^0.5
Column Diameter given Maximum Vapor Rate and Maximum Vapor Velocity
​ Go Column Diameter = sqrt((4*Vapor Mass Flowrate)/(pi*Vapor Density in Distillation*Maximum Allowable Vapor Velocity))
Tower Cross Sectional Area given Gas Volumetric Flow and Flooding Velocity
​ Go Tower Cross Sectional Area = Volumetric Gas Flow/((Fractional Approach to Flooding Velocity*Flooding Velocity)*(1-Fractional Downcomer Area))
Minimum External Reflux given Compositions
​ Go External Reflux Ratio = (Distillate Composition-Equilibrium Vapor Composition)/(Equilibrium Vapor Composition-Equilibrium Liquid Composition)
Maximum Allowable Mass Velocity using Bubble Cap Trays
​ Go Maximum Allowable Mass Velocity = Entrainment Factor*(Vapor Density in Distillation*(Liquid Density-Vapor Density in Distillation)^(1/2))
Minimum Internal Reflux given Compositions
​ Go Internal Reflux Ratio = (Distillate Composition-Equilibrium Vapor Composition)/(Distillate Composition-Equilibrium Liquid Composition)
Dry Plate Pressure Drop in Distillation Column Design
​ Go Dry Plate Head Loss = 51*((Vapor Velocity Based on Hole Area/Orifice Coefficient)^2)*(Vapor Density in Distillation/Liquid Density)
Flooding Velocity in Distillation Column Design
​ Go Flooding Velocity = Capacity Factor*((Liquid Density-Vapor Density in Distillation)/Vapor Density in Distillation)^0.5
Weep Point Velocity in Distillation Column Design
​ Go Weep Point Vapor Velocity Based on Hole Area = (Weep Point Correlation Constant-0.90*(25.4-Hole Diameter))/((Vapor Density in Distillation)^0.5)
Liquid Vapor Flow Factor in Distillation Column Design
​ Go Flow Factor = (Liquid Mass Flowrate/Vapor Mass Flowrate)*((Vapor Density in Distillation/Liquid Density)^0.5)
Downcomer Residence Time in Distillation Column
​ Go Residence Time = (Downcomer Area*Clear Liquid Backup*Liquid Density)/Liquid Mass Flowrate
Internal Reflux Ratio Based on Liquid and Distillate Flowrates
​ Go Internal Reflux Ratio = Liquid Reflux Flowrate/(Liquid Reflux Flowrate+Distillate Flowrate)
Column Diameter Based on Vapor Flowrate and Mass Velocity of Vapor
​ Go Column Diameter = ((4*Vapor Mass Flowrate)/(pi*Maximum Allowable Mass Velocity))^(1/2)
Head Loss in Downcomer of Tray Tower
​ Go Downcomer Headloss = 166*((Liquid Mass Flowrate/(Liquid Density*Downcomer Area)))^2
Height of Liquid Crest over Weir
​ Go Weir Crest = (750/1000)*((Liquid Mass Flowrate/(Weir Length*Liquid Density))^(2/3))
Active Area given Gas Volumetric Flow and Flow Velocity
​ Go Active Area = Volumetric Gas Flow/(Fractional Downcomer Area*Flooding Velocity)
Fractional Downcomer Area given Total Cross Sectional Area
​ Go Fractional Downcomer Area = 2*(Downcomer Area/Tower Cross Sectional Area)
Fractional Active Area given Downcomer Area and Total Column Area
​ Go Fractional Active Area = 1-2*(Downcomer Area/Tower Cross Sectional Area)
Internal Reflux Ratio Given External Reflux Ratio
​ Go Internal Reflux Ratio = External Reflux Ratio/(External Reflux Ratio+1)
Tower Cross Sectional Area given Fractional Active Area
​ Go Tower Cross Sectional Area = Active Area/(1-Fractional Downcomer Area)
Tower Cross Sectional Area given Active Area
​ Go Tower Cross Sectional Area = Active Area/(1-Fractional Downcomer Area)
Clearance Area under Downcomer given Weir Length and Apron Height
​ Go Clearance Area Under Downcomer = Apron Height*Weir Length
Fractional Active Area given Fractional Downcomer Area
​ Go Fractional Active Area = 1-Fractional Downcomer Area
Residual Head Loss in Pressure in Distillation Column
​ Go Residual Head Loss = (12.5*10^3)/Liquid Density

Dry Plate Pressure Drop in Distillation Column Design Formula

Dry Plate Head Loss = 51*((Vapor Velocity Based on Hole Area/Orifice Coefficient)^2)*(Vapor Density in Distillation/Liquid Density)
hd = 51*((Uh/Co)^2)*(ρV/ρL)

What is Dry Plate Pressure Drop?

Dry Plate Pressure Drop refers to the pressure drop experienced by vapor as it flows through a single tray or plate without any liquid flow. This term is used to describe the pressure drop caused by the vapor's passage over the tray surface without encountering any liquid downflow or vapor-liquid interactions.

How to Calculate Dry Plate Pressure Drop in Distillation Column Design?

Dry Plate Pressure Drop in Distillation Column Design calculator uses Dry Plate Head Loss = 51*((Vapor Velocity Based on Hole Area/Orifice Coefficient)^2)*(Vapor Density in Distillation/Liquid Density) to calculate the Dry Plate Head Loss, The Dry Plate Pressure Drop in Distillation Column Design formula is defined as the loss in Pressure due to flow of Vapor through the hole (orifice) of tray in a column. Dry Plate Head Loss is denoted by hd symbol.

How to calculate Dry Plate Pressure Drop in Distillation Column Design using this online calculator? To use this online calculator for Dry Plate Pressure Drop in Distillation Column Design, enter Vapor Velocity Based on Hole Area (Uh), Orifice Coefficient (Co), Vapor Density in Distillation V) & Liquid Density L) and hit the calculate button. Here is how the Dry Plate Pressure Drop in Distillation Column Design calculation can be explained with given input values -> 52.21576 = 51*((20.2585/0.83)^2)*(1.71/995).

FAQ

What is Dry Plate Pressure Drop in Distillation Column Design?
The Dry Plate Pressure Drop in Distillation Column Design formula is defined as the loss in Pressure due to flow of Vapor through the hole (orifice) of tray in a column and is represented as hd = 51*((Uh/Co)^2)*(ρVL) or Dry Plate Head Loss = 51*((Vapor Velocity Based on Hole Area/Orifice Coefficient)^2)*(Vapor Density in Distillation/Liquid Density). Vapor Velocity Based on Hole Area is defined as the actual vapor velocity on the basis of hole area available to the vapor passing through the column, Orifice Coefficient is a constant that depends on plate thickness, hole diameter and the ratio of hole to perforated area, Vapor Density in Distillation is defined as the ratio of mass to the volume of vapor at particular temperature in a distillation Column & Liquid Density is defined as the ratio of mass of given fluid with respect to the volume that it occupies.
How to calculate Dry Plate Pressure Drop in Distillation Column Design?
The Dry Plate Pressure Drop in Distillation Column Design formula is defined as the loss in Pressure due to flow of Vapor through the hole (orifice) of tray in a column is calculated using Dry Plate Head Loss = 51*((Vapor Velocity Based on Hole Area/Orifice Coefficient)^2)*(Vapor Density in Distillation/Liquid Density). To calculate Dry Plate Pressure Drop in Distillation Column Design, you need Vapor Velocity Based on Hole Area (Uh), Orifice Coefficient (Co), Vapor Density in Distillation V) & Liquid Density L). With our tool, you need to enter the respective value for Vapor Velocity Based on Hole Area, Orifice Coefficient, Vapor Density in Distillation & Liquid Density and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!