Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has created this Calculator and 100+ more calculators!
Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 500+ more calculators!

11 Other formulas that you can solve using the same Inputs

Allowable Bearing Pressure When Flange Thickness for H shaped Column is Given
Allowable bearing stress=4*Column load/((Column depth+Width of Flange)^2-(-4*Flange thickness of H shaped columns+Column depth+Width of Flange)^2) GO
Stress for Concentrated Load Applied at a Distance Larger than Depth of Beam
Allowable compressive stress=Column load/(Web thickness*(Minimum bearing length+5*Distance from flange to web fillet)) GO
Web Thickness when Stress is Given
Web thickness=Column load/(Allowable compressive stress*(Minimum bearing length+5*Distance from flange to web fillet)) GO
Plate Length
Length of plate=sqrt(Area required by base plate)+(0.5*((0.95*Column depth)-(0.80*Width of Flange))) GO
Column Depth When Plate Length is Given
Column depth=(Width of Flange+(2.5*(Length of plate-sqrt(Area required by base plate))))/1.1875 GO
Maximum Unsupported Length of Compression Flange-1
Maximum unsupported length=76.0*Width of Flange/sqrt(minimum specified yield stress of steel) GO
Column Flange Width When Plate Length is Given
Width of Flange=1.1875*Column depth-(2.5*(Length of plate-sqrt(Area required by base plate))) GO
Area Required by the Base Plate
Area required by base plate=Column load/(0.7*Specified compressive strength of concrete) GO
Equivalent Cantilever Dimension
Equivalent Cantilever Dimension=(1/4)*sqrt(Depth of Section of Column*Width of Flange) GO
Diameter of Roller or Rocker When Allowable Bearing Stress is Given
Diameter =30.303*Allowable bearing stress/(Yield stress of steel-13) GO
Yield strength when allowable stress in the flange is given
Yield Strength=Allowable bearing stress/0.66 GO

Flange Thickness for H shaped Columns Formula

Flange thickness of H shaped columns=0.25*(Column depth+Width of Flange)-0.25*(sqrt((Column depth+Width of Flange)^2-((4*Column load)/Allowable bearing stress)))
L=0.25*(d+b<sub>f)-0.25*(sqrt((d+b<sub>f)^2-((4*R)/F<sub>p</sub>)))
More formulas
Area Required by the Base Plate GO
Column Load if Area Required by the Base Plate is Given GO
Plate Length GO
Column Flange Width When Plate Length is Given GO
Column Depth When Plate Length is Given GO
Thickness of Plate GO
Bearing Pressure When Plate Thickness is Given GO
Allowable Bearing Pressure When Flange Thickness for H shaped Column is Given GO
Thickness of Plate When Flange Thickness for H shaped Column is Given GO

What are columns?

It is the main structural member design to take axial load that is gravity load ,bending moment ,shear forces and buckling and horizontal load like earthquake load and wind load.

How to Calculate Flange Thickness for H shaped Columns?

Flange Thickness for H shaped Columns calculator uses Flange thickness of H shaped columns=0.25*(Column depth+Width of Flange)-0.25*(sqrt((Column depth+Width of Flange)^2-((4*Column load)/Allowable bearing stress))) to calculate the Flange thickness of H shaped columns, The Flange Thickness for H shaped Columns is defined using the parameters, column width and depth, bearing stress and column load. . Flange thickness of H shaped columns and is denoted by L symbol.

How to calculate Flange Thickness for H shaped Columns using this online calculator? To use this online calculator for Flange Thickness for H shaped Columns, enter Column depth (d), Width of Flange (bf), Column load (R) and Allowable bearing stress (Fp) and hit the calculate button. Here is how the Flange Thickness for H shaped Columns calculation can be explained with given input values -> 1.771243 = 0.25*(0.05+0.01)-0.25*(sqrt((0.05+0.01)^2-((4*100000)/500000000))).

FAQ

What is Flange Thickness for H shaped Columns?
The Flange Thickness for H shaped Columns is defined using the parameters, column width and depth, bearing stress and column load. and is represented as L=0.25*(d+bf)-0.25*(sqrt((d+bf)^2-((4*R)/Fp))) or Flange thickness of H shaped columns=0.25*(Column depth+Width of Flange)-0.25*(sqrt((Column depth+Width of Flange)^2-((4*Column load)/Allowable bearing stress))). Column depth is the horizontal length of column cross section, Width of Flange is defined as the spacing of the beam, which is the same as the distance between the middle points of the adjacent spans of the slab, Column load is the load acting on the column cross section and Allowable bearing stress is the maximum limit of stress allowed or permitted for bearing on concrete or masonry. .
How to calculate Flange Thickness for H shaped Columns?
The Flange Thickness for H shaped Columns is defined using the parameters, column width and depth, bearing stress and column load. is calculated using Flange thickness of H shaped columns=0.25*(Column depth+Width of Flange)-0.25*(sqrt((Column depth+Width of Flange)^2-((4*Column load)/Allowable bearing stress))). To calculate Flange Thickness for H shaped Columns, you need Column depth (d), Width of Flange (bf), Column load (R) and Allowable bearing stress (Fp). With our tool, you need to enter the respective value for Column depth, Width of Flange, Column load and Allowable bearing stress and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Share Image
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!