Flow Diversion for Side Weir Solution

STEP 0: Pre-Calculation Summary
Formula Used
Volume Flow Rate = 3.32*Length of Weir^(0.83)*Depth of Flow Over Weir^(1.67)
Q = 3.32*Lweir^(0.83)*h^(1.67)
This formula uses 3 Variables
Variables Used
Volume Flow Rate - (Measured in Cubic Meter per Second) - Volume Flow Rate is the volume of fluid that passes per unit of time.
Length of Weir - (Measured in Meter) - Length of Weir is defined as the total length of the weir calculated when the flow rate of the diversion weir is given.
Depth of Flow Over Weir - (Measured in Meter) - Depth of Flow Over Weir is the total depth of flow over the weir at down-stream end.
STEP 1: Convert Input(s) to Base Unit
Length of Weir: 0.6 Meter --> 0.6 Meter No Conversion Required
Depth of Flow Over Weir: 0.8 Meter --> 0.8 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Q = 3.32*Lweir^(0.83)*h^(1.67) --> 3.32*0.6^(0.83)*0.8^(1.67)
Evaluating ... ...
Q = 1.49680043187199
STEP 3: Convert Result to Output's Unit
1.49680043187199 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
1.49680043187199 1.4968 Cubic Meter per Second <-- Volume Flow Rate
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

7 Controlling Sewer-Water Flow Calculators

Head given Area for Siphon Throat
​ Go Head of Liquid = (Volume Flow Rate/(Area for Siphon Throat*Coefficient of Discharge))^(2)*(1/(2*Acceleration due to Gravity))
Coefficient of Discharge given Area for Siphon Throat
​ Go Coefficient of Discharge = Volume Flow Rate/(Area for Siphon Throat*(2*Acceleration due to Gravity*Head of Liquid)^(1/2))
Area for Siphon Throat
​ Go Area for Siphon Throat = Volume Flow Rate/(Coefficient of Discharge*(2*Acceleration due to Gravity*Head of Liquid)^(1/2))
Discharge given Area for Siphon Throat
​ Go Volume Flow Rate = Area for Siphon Throat*Coefficient of Discharge*(2*Acceleration due to Gravity*Head of Liquid)^(1/2)
Depth of Flow over Weir given Flow Diversion
​ Go Depth of Flow Over Weir = (Volume Flow Rate/(3.32*(Length of Weir)^0.83))^(1/1.67)
Length of Weir given Flow Diversion
​ Go Length of Weir = (Volume Flow Rate/(3.32*Depth of Flow Over Weir^1.67))^(1/0.83)
Flow Diversion for Side Weir
​ Go Volume Flow Rate = 3.32*Length of Weir^(0.83)*Depth of Flow Over Weir^(1.67)

Flow Diversion for Side Weir Formula

Volume Flow Rate = 3.32*Length of Weir^(0.83)*Depth of Flow Over Weir^(1.67)
Q = 3.32*Lweir^(0.83)*h^(1.67)

What is weir?

Weir is a low head dam is a barrier across the width of a river that alters the flow characteristics of water and usually results in a change in the height of the river level.

How to Calculate Flow Diversion for Side Weir?

Flow Diversion for Side Weir calculator uses Volume Flow Rate = 3.32*Length of Weir^(0.83)*Depth of Flow Over Weir^(1.67) to calculate the Volume Flow Rate, The Flow diversion for side weir formula is defined as the flow which takes place in a diversion weir. A diversion weir is a low obstruction that is built across a river or canal to raise the water level, or in parallel to divert the water. Volume Flow Rate is denoted by Q symbol.

How to calculate Flow Diversion for Side Weir using this online calculator? To use this online calculator for Flow Diversion for Side Weir, enter Length of Weir (Lweir) & Depth of Flow Over Weir (h) and hit the calculate button. Here is how the Flow Diversion for Side Weir calculation can be explained with given input values -> 1.4968 = 3.32*0.6^(0.83)*0.8^(1.67).

FAQ

What is Flow Diversion for Side Weir?
The Flow diversion for side weir formula is defined as the flow which takes place in a diversion weir. A diversion weir is a low obstruction that is built across a river or canal to raise the water level, or in parallel to divert the water and is represented as Q = 3.32*Lweir^(0.83)*h^(1.67) or Volume Flow Rate = 3.32*Length of Weir^(0.83)*Depth of Flow Over Weir^(1.67). Length of Weir is defined as the total length of the weir calculated when the flow rate of the diversion weir is given & Depth of Flow Over Weir is the total depth of flow over the weir at down-stream end.
How to calculate Flow Diversion for Side Weir?
The Flow diversion for side weir formula is defined as the flow which takes place in a diversion weir. A diversion weir is a low obstruction that is built across a river or canal to raise the water level, or in parallel to divert the water is calculated using Volume Flow Rate = 3.32*Length of Weir^(0.83)*Depth of Flow Over Weir^(1.67). To calculate Flow Diversion for Side Weir, you need Length of Weir (Lweir) & Depth of Flow Over Weir (h). With our tool, you need to enter the respective value for Length of Weir & Depth of Flow Over Weir and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Volume Flow Rate?
In this formula, Volume Flow Rate uses Length of Weir & Depth of Flow Over Weir. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Volume Flow Rate = Area for Siphon Throat*Coefficient of Discharge*(2*Acceleration due to Gravity*Head of Liquid)^(1/2)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!