Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 500+ more calculators!
Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 500+ more calculators!

11 Other formulas that you can solve using the same Inputs

Negative Sequence Voltage Using a-phase Current (LGF)
Negative Sequence Voltage=(Fault Impedance *a-phase Current )-Positive Sequence Voltage-Zero Sequence Voltage GO
Positive Sequence Voltage Using a-phase Current
Positive Sequence Voltage=(Fault Impedance *a-phase Current )-Negative Sequence Voltage-Zero Sequence Voltage GO
Neutral Impedance For Star Connected Load Using Zero Sequence Voltage
Neutral Impedance =((Zero Sequence Voltage/Zero Sequence Current )-Star Impedance )/3 GO
Star Impedance For Star Connected Load Using Zero Sequence Current
Star Impedance =(Zero Sequence Voltage/Zero Sequence Current )-(3*Neutral Impedance ) GO
Leakage Impedance For Transformer Using Zero Sequence Current
Leakage Impedance=(Zero Sequence Voltage/Zero Sequence Current )-3*Neutral Impedance GO
Zero Sequence current For Star Connected Load
Zero Sequence Current =Zero Sequence Voltage/(Star Impedance +(3*Neutral Impedance )) GO
Star Impedance For Star Connected Load Using Zero Sequence Voltage
Star Impedance =Zero Sequence Voltage/Zero Sequence Current -(3*Neutral Impedance ) GO
Zero Sequence Voltage For Star Connected Load
Zero Sequence Voltage=(Star Impedance +3*Neutral Impedance )*Zero Sequence Current GO
Zero Sequence Impedance For Delta Connected Load
Zero Sequence Impedance=Zero Sequence Voltage/Zero Sequence Current GO
Zero Sequence Impedance For transformer
Zero Sequence Impedance=Zero Sequence Voltage/Zero Sequence Current GO
Zero Sequence Impedance For Star Connected Load
Zero Sequence Impedance=Star Impedance +(3*Neutral Impedance ) GO

5 Other formulas that calculate the same Output

Leakage Impedance For Transformer Using Zero Sequence Current
Leakage Impedance=(Zero Sequence Voltage/Zero Sequence Current )-3*Neutral Impedance GO
Leakage Impedance For Transformer Using Positive Sequence Voltage
Leakage Impedance=Positive Sequence Voltage/Positive Sequence Current GO
Leakage Impedance For transformer Using Negative Sequence Voltage
Leakage Impedance=Negative Sequence Voltage/Negative Sequence Current GO
Leakage Impedance For Transformer Using Positive Sequence Current
Leakage Impedance=Positive Sequence Voltage/Positive Sequence Current GO
Leakage Impedance For Transformer Using Negative Sequence Current
Leakage Impedance=Negative Sequence Voltage/Negative Sequence Current GO

Leakage Impedance For transformer Using Zero Sequence Voltage Formula

Leakage Impedance=(Zero Sequence Voltage/Zero Sequence Current )-3*Neutral Impedance
Zleakage=(V0/I0)-3*Zn
More formulas
Zero Sequence Impedance For Star Connected Load GO
Negative Sequence Impedance For Star Connected Load GO
Positive Sequence Impedance For Star Connected Load GO
Positive Sequence Impedance For Delta Connected Load GO
Negative Sequence Impedance For Delta Connected Load GO
Zero Sequence Impedance For Delta Connected Load GO
Positive Sequence Impedance For transformer GO
Negative Sequence Impedance For Transformer GO
Zero Sequence Impedance For transformer GO
Symmetric Component Voltage Using Sequence Impedance GO
Sequence Impedance GO
Symmetric Component Current Using Sequence Impedance GO
Negative Sequence Voltage For Star Connected Load GO
Zero Sequence Voltage For Star Connected Load GO
Positive Sequence Voltage For Delta Connected Load GO
Positive Sequence Voltage For Star Connected Load GO
Negative Sequence Voltage For Delta Connected Load GO
Positive Sequence Current For Star Connected Load GO
Negative Sequence Current For Star Connected Load GO
Zero Sequence current For Star Connected Load GO
Negative Phase Current For Delta Connected Load GO
Positive Sequence Current For Delta Connected Load GO
Leakage Impedance For Transformer Using Positive Sequence Voltage GO
Leakage Impedance For transformer Using Negative Sequence Voltage GO
Leakage Impedance For Transformer Using Positive Sequence Current GO
Leakage Impedance For Transformer Using Negative Sequence Current GO
Leakage Impedance For Transformer Using Zero Sequence Current GO
Star Impedance For Star Connected Load Using Negative Sequence Voltage GO
Star Impedance For Star Connected Load Using Positive Sequence Voltage GO
Star Impedance For Star Connected Load Using Zero Sequence Voltage GO
Neutral Impedance For Star Connected Load Using Zero Sequence Voltage GO
Star Impedance For Star Connected Load Using Negative Sequence Current GO
Star Impedance For Star Connected Load Using Positive Sequence Current GO
Star Impedance For Star Connected Load Using Zero Sequence Current GO
Delta Impedance For Delta Connected Load Using Negative Sequence Voltage GO
Positive Sequence Voltage (LLF) GO
Star Impedance Using Delta Impedance GO

What are the Sequence Components?

The positive sequence consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. The negative sequence consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation. Zero sequence consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counterclockwise together.

How to Calculate Leakage Impedance For transformer Using Zero Sequence Voltage?

Leakage Impedance For transformer Using Zero Sequence Voltage calculator uses Leakage Impedance=(Zero Sequence Voltage/Zero Sequence Current )-3*Neutral Impedance to calculate the Leakage Impedance, The Leakage Impedance For transformer Using Zero Sequence Voltage formula is defined as the part of the impedance of a transformer that corresponds to the leakage flux into the sequence network. Leakage Impedance and is denoted by Zleakage symbol.

How to calculate Leakage Impedance For transformer Using Zero Sequence Voltage using this online calculator? To use this online calculator for Leakage Impedance For transformer Using Zero Sequence Voltage, enter Zero Sequence Voltage (V0), Zero Sequence Current (I0) and Neutral Impedance (Zn) and hit the calculate button. Here is how the Leakage Impedance For transformer Using Zero Sequence Voltage calculation can be explained with given input values -> -1.371429 = (3/7)-3*0.6.

FAQ

What is Leakage Impedance For transformer Using Zero Sequence Voltage?
The Leakage Impedance For transformer Using Zero Sequence Voltage formula is defined as the part of the impedance of a transformer that corresponds to the leakage flux into the sequence network and is represented as Zleakage=(V0/I0)-3*Zn or Leakage Impedance=(Zero Sequence Voltage/Zero Sequence Current )-3*Neutral Impedance . Zero Sequence Voltage consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counterclockwise together, Zero Sequence Current consists of a balanced three-phase current, phasors of which all have the same phase angles and rotate counterclockwise together and Neutral Impedance is defined as the impedance of the neutral.
How to calculate Leakage Impedance For transformer Using Zero Sequence Voltage?
The Leakage Impedance For transformer Using Zero Sequence Voltage formula is defined as the part of the impedance of a transformer that corresponds to the leakage flux into the sequence network is calculated using Leakage Impedance=(Zero Sequence Voltage/Zero Sequence Current )-3*Neutral Impedance . To calculate Leakage Impedance For transformer Using Zero Sequence Voltage, you need Zero Sequence Voltage (V0), Zero Sequence Current (I0) and Neutral Impedance (Zn). With our tool, you need to enter the respective value for Zero Sequence Voltage, Zero Sequence Current and Neutral Impedance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Leakage Impedance?
In this formula, Leakage Impedance uses Zero Sequence Voltage, Zero Sequence Current and Neutral Impedance . We can use 5 other way(s) to calculate the same, which is/are as follows -
  • Leakage Impedance=Positive Sequence Voltage/Positive Sequence Current
  • Leakage Impedance=Negative Sequence Voltage/Negative Sequence Current
  • Leakage Impedance=Positive Sequence Voltage/Positive Sequence Current
  • Leakage Impedance=Negative Sequence Voltage/Negative Sequence Current
  • Leakage Impedance=(Zero Sequence Voltage/Zero Sequence Current )-3*Neutral Impedance
Share Image
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!