Retention Volume using Column Efficiency Solution

STEP 0: Pre-Calculation Summary
Formula Used
Retention Volume = Width of Chromatographic Peak*(sqrt(Column Efficiency/16))
VR = Wb*(sqrt(N/16))
This formula uses 1 Functions, 3 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Retention Volume - (Measured in Cubic Meter) - The Retention Volume is defined as the volume of the mobile phase required to elute the solute from the column.
Width of Chromatographic Peak - (Measured in Meter) - Width of Chromatographic Peak is the distance between points where lines tangent to the peak's left and right inflection points intersect the baseline.
Column Efficiency - Column Efficiency, also known as plate count, is a measure of the dispersion of a peak.
STEP 1: Convert Input(s) to Base Unit
Width of Chromatographic Peak: 25 Millimeter --> 0.025 Meter (Check conversion here)
Column Efficiency: 5.5 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
VR = Wb*(sqrt(N/16)) --> 0.025*(sqrt(5.5/16))
Evaluating ... ...
VR = 0.0146575492494482
STEP 3: Convert Result to Output's Unit
0.0146575492494482 Cubic Meter -->14.6575492494482 Liter (Check conversion here)
FINAL ANSWER
14.6575492494482 14.65755 Liter <-- Retention Volume
(Calculation completed in 00.006 seconds)

Credits

Created by Soupayan banerjee
National University of Judicial Science (NUJS), Kolkata
Soupayan banerjee has created this Calculator and 200+ more calculators!
Verified by Pratibha
Amity Institute Of Applied Sciences (AIAS, Amity University), Noida, India
Pratibha has verified this Calculator and 50+ more calculators!

17 Osmolality Calculators

Peak Resolution in Chromatography
Go Peak Resolution = (Retention Volume of Molecule 2-Retention Volume of Molecule 1)/((Width of Chromatographic Peak of Molecule 1+Widths of Chromatographic Peak of Molecule 2)/2)
Blood Urea Nitrogen using Calculated Serum Osmolality
Go Blood Urea Nitrogen = 2.8*((Calculated Serum Osmolality)-(2*Serum Sodium)-(Serum Glucose/18))
Serum Glucose using Calculated Serum Osmolality
Go Serum Glucose = 18*((Calculated Serum Osmolality)-(2*Serum Sodium)-(Blood Urea Nitrogen/2.8))
Serum Sodium using Calculated Serum Osmolality
Go Serum Sodium = ((Calculated Serum Osmolality)-(Serum Glucose/18)-(Blood Urea Nitrogen/2.8))/2
Calculated Serum Osmolality
Go Calculated Serum Osmolality = (2*Serum Sodium)+(Serum Glucose/18)+(Blood Urea Nitrogen/2.8)
Width of Chromatographic Peak using Column Efficiency
Go Width of Chromatographic Peak = Retention Volume/(sqrt(Column Efficiency/16))
Retention Volume using Column Efficiency
Go Retention Volume = Width of Chromatographic Peak*(sqrt(Column Efficiency/16))
Column Efficiency in Chromatography
Go Column Efficiency = 16*((Retention Volume/ Width of Chromatographic Peak)^2)
Increase of Splicing Potential by Wild-type Sequence
Go Splicing Potential = log10(Weight Factor for Increase of Splicing Potential)
Calculated Serum Osmolality using Osmolar Gap
Go Calculated Serum Osmolality = Measured Osmolality-Osmolar Gap
Measured Osmolality using Osmolar Gap
Go Measured Osmolality = Osmolar Gap+Calculated Serum Osmolality
Osmolar Gap
Go Osmolar Gap = Measured Osmolality-Calculated Serum Osmolality
Total Volume of Mobile Phase within Column given Retention Factor
Go Void Volume = Retention Volume/(Retention Factor+1)
Retention Volume using Retention Factor
Go Retention Volume = Void Volume*(Retention Factor+1)
Decrease of Splicing Potential by Mutant Sequence
Go Splicing Potential = -log10(Weight Factor)
Plasma Osmolality
Go Plasma Osmolality = (2*Sodium Concentration in Plasma)
Plasma Concentration using Plasma Osmolality
Go Sodium Concentration in Plasma = Plasma Osmolality/2

Retention Volume using Column Efficiency Formula

Retention Volume = Width of Chromatographic Peak*(sqrt(Column Efficiency/16))
VR = Wb*(sqrt(N/16))

What is Column Chromatography?

Column chromatography separates substances based on differential adsorption of compounds to the adsorbent as the compounds move through the column at different rates which allow them to get separated in fractions. This technique can be used on a small scale as well as large scale to purify materials that can be used in future experiments. This method is a type of adsorption chromatography technique.

How to Calculate Retention Volume using Column Efficiency?

Retention Volume using Column Efficiency calculator uses Retention Volume = Width of Chromatographic Peak*(sqrt(Column Efficiency/16)) to calculate the Retention Volume, The Retention Volume using Column Efficiency formula is defined as the volume of eluent carrier gas admitted to the column between the injection of the sample and the emergence of the peak maximum of the specified component. Retention Volume is denoted by VR symbol.

How to calculate Retention Volume using Column Efficiency using this online calculator? To use this online calculator for Retention Volume using Column Efficiency, enter Width of Chromatographic Peak (Wb) & Column Efficiency (N) and hit the calculate button. Here is how the Retention Volume using Column Efficiency calculation can be explained with given input values -> 14657.55 = 0.025*(sqrt(5.5/16)).

FAQ

What is Retention Volume using Column Efficiency?
The Retention Volume using Column Efficiency formula is defined as the volume of eluent carrier gas admitted to the column between the injection of the sample and the emergence of the peak maximum of the specified component and is represented as VR = Wb*(sqrt(N/16)) or Retention Volume = Width of Chromatographic Peak*(sqrt(Column Efficiency/16)). Width of Chromatographic Peak is the distance between points where lines tangent to the peak's left and right inflection points intersect the baseline & Column Efficiency, also known as plate count, is a measure of the dispersion of a peak.
How to calculate Retention Volume using Column Efficiency?
The Retention Volume using Column Efficiency formula is defined as the volume of eluent carrier gas admitted to the column between the injection of the sample and the emergence of the peak maximum of the specified component is calculated using Retention Volume = Width of Chromatographic Peak*(sqrt(Column Efficiency/16)). To calculate Retention Volume using Column Efficiency, you need Width of Chromatographic Peak (Wb) & Column Efficiency (N). With our tool, you need to enter the respective value for Width of Chromatographic Peak & Column Efficiency and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Retention Volume?
In this formula, Retention Volume uses Width of Chromatographic Peak & Column Efficiency. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Retention Volume = Void Volume*(Retention Factor+1)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!