How to Calculate Sewage Discharge given Oxygen Required in Aeration Tank?
Sewage Discharge given Oxygen Required in Aeration Tank calculator uses Sewage Discharge = ((Ratio of BOD to Ultimate BOD*(Theoretical Oxygen Requirement+(1.42*Volume of Wasted Sludge per day*MLSS in returned or wasted sludge)))/(Influent BOD-Effluent BOD)) to calculate the Sewage Discharge, Sewage Discharge given Oxygen Required in Aeration Tank calculates sewage discharge when we have prior information of other parameters used. Sewage Discharge is denoted by Qs symbol.
How to calculate Sewage Discharge given Oxygen Required in Aeration Tank using this online calculator? To use this online calculator for Sewage Discharge given Oxygen Required in Aeration Tank, enter Ratio of BOD to Ultimate BOD (f), Theoretical Oxygen Requirement (O2), Volume of Wasted Sludge per day (Qw), MLSS in returned or wasted sludge (XR), Influent BOD (Qi) & Effluent BOD (Qo) and hit the calculate button. Here is how the Sewage Discharge given Oxygen Required in Aeration Tank calculation can be explained with given input values -> 3.997037 = ((1.6*(2.89351851851852E-11+(1.42*9.5*0.002)))/(0.0112-0.0004)).