Temperature given Reoxygenation Coefficient at T degree Celsius Solution

STEP 0: Pre-Calculation Summary
Formula Used
Temperature = log((Reoxygenation coefficient/Reoxygenation coefficient at temperature 20),1.016)+20
T = log((KR/KR(20)),1.016)+20
This formula uses 1 Functions, 3 Variables
Functions Used
log - Logarithmic function is an inverse function to exponentiation., log(Base, Number)
Variables Used
Temperature - (Measured in Kelvin) - Temperature is the degree or intensity of heat present in a substance or object.
Reoxygenation coefficient - (Measured in 1 Per Second) - Reoxygenation coefficient implies the higher the flow velocity, the higher the re-oxygenation coefficient.
Reoxygenation coefficient at temperature 20 - (Measured in 1 Per Second) - Reoxygenation coefficient at temperature 20 is the BOD rate constant at 20°C temperature.
STEP 1: Convert Input(s) to Base Unit
Reoxygenation coefficient: 0.1 1 Per Day --> 1.15740740740741E-06 1 Per Second (Check conversion here)
Reoxygenation coefficient at temperature 20: 0.65 1 Per Day --> 7.52314814814815E-06 1 Per Second (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
T = log((KR/KR(20)),1.016)+20 --> log((1.15740740740741E-06/7.52314814814815E-06),1.016)+20
Evaluating ... ...
T = 19.9915197506701
STEP 3: Convert Result to Output's Unit
19.9915197506701 Kelvin --> No Conversion Required
FINAL ANSWER
19.9915197506701 19.99152 Kelvin <-- Temperature
(Calculation completed in 00.004 seconds)

Credits

Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 600+ more calculators!

6 Reoxygenation Coefficient Calculators

Reoxygenation Coefficient given Critical Oxygen Deficit
Go Reoxygenation coefficient = Deoxygenation Constant*Oxygen Equivalent*(10^(-Deoxygenation Constant*Critical time))/Critical oxygen deficit
Temperature given Reoxygenation Coefficient at T degree Celsius
Go Temperature = log((Reoxygenation coefficient/Reoxygenation coefficient at temperature 20),1.016)+20
Reoxygenation Coefficients
Go Reoxygenation coefficient = Reoxygenation coefficient at Temperature 20*(1.016)^(Temperature-20)
Stream Depth given Reoxygenation Coefficient
Go Depth Of stream = (3.9*sqrt(Velocity)/Reoxygenation coefficient)^(1/1.5)
Reoxygenation Coefficient at 20 degree Celsius
Go Reoxygenation coefficient at temperature 20 = Reoxygenation coefficient/((1.016)^(Temperature-20))
Reoxygenation Coefficient given Self Purification Constant
Go Reoxygenation coefficient = Deoxygenation Constant*Self purification constant

Temperature given Reoxygenation Coefficient at T degree Celsius Formula

Temperature = log((Reoxygenation coefficient/Reoxygenation coefficient at temperature 20),1.016)+20
T = log((KR/KR(20)),1.016)+20

What is reoxygenation coefficient?

Reoxygenation coefficient is the BOD rate constant process of adding oxygen to the body of water. It is expressed in per day.

How to Calculate Temperature given Reoxygenation Coefficient at T degree Celsius?

Temperature given Reoxygenation Coefficient at T degree Celsius calculator uses Temperature = log((Reoxygenation coefficient/Reoxygenation coefficient at temperature 20),1.016)+20 to calculate the Temperature, The Temperature given Reoxygenation Coefficient at T degree Celsius is the temperature at which oxygen is added to the water body. It is expressed in °C. Temperature is denoted by T symbol.

How to calculate Temperature given Reoxygenation Coefficient at T degree Celsius using this online calculator? To use this online calculator for Temperature given Reoxygenation Coefficient at T degree Celsius, enter Reoxygenation coefficient (KR) & Reoxygenation coefficient at temperature 20 (KR(20)) and hit the calculate button. Here is how the Temperature given Reoxygenation Coefficient at T degree Celsius calculation can be explained with given input values -> 19.99152 = log((1.15740740740741E-06/7.52314814814815E-06),1.016)+20.

FAQ

What is Temperature given Reoxygenation Coefficient at T degree Celsius?
The Temperature given Reoxygenation Coefficient at T degree Celsius is the temperature at which oxygen is added to the water body. It is expressed in °C and is represented as T = log((KR/KR(20)),1.016)+20 or Temperature = log((Reoxygenation coefficient/Reoxygenation coefficient at temperature 20),1.016)+20. Reoxygenation coefficient implies the higher the flow velocity, the higher the re-oxygenation coefficient & Reoxygenation coefficient at temperature 20 is the BOD rate constant at 20°C temperature.
How to calculate Temperature given Reoxygenation Coefficient at T degree Celsius?
The Temperature given Reoxygenation Coefficient at T degree Celsius is the temperature at which oxygen is added to the water body. It is expressed in °C is calculated using Temperature = log((Reoxygenation coefficient/Reoxygenation coefficient at temperature 20),1.016)+20. To calculate Temperature given Reoxygenation Coefficient at T degree Celsius, you need Reoxygenation coefficient (KR) & Reoxygenation coefficient at temperature 20 (KR(20)). With our tool, you need to enter the respective value for Reoxygenation coefficient & Reoxygenation coefficient at temperature 20 and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!