Thickness of base metal for desired cooling rate Solution

STEP 0: Pre-Calculation Summary
Formula Used
Thickness = Net Heat Supplied per Unit Length*sqrt(Cooling Rate/(2*pi*Thermal Conductivity*Density*Specific Heat Capacity*((Temperature to Calculate Cooling Rate-Ambient Temperature)^3)))
z = HNet*sqrt(R/(2*pi*k*ρ*Qc*((Tc-ta)^3)))
This formula uses 1 Constants, 1 Functions, 8 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Thickness - (Measured in Meter) - Thickness of the base metal is the thickness of the base metal and is denoted by h symbol.
Net Heat Supplied per Unit Length - (Measured in Joule per Meter) - Net heat supplied per unit length can also be converted to newton since energy is newton multiplied meter.
Cooling Rate - (Measured in Kelvin per Second) - Cooling Rate is the time rate of decrease of temperature of a particular material.
Thermal Conductivity - (Measured in Watt per Meter per K) - Thermal Conductivity is rate of heat passes through specified material, expressed as amount of heat flows per unit time through a unit area with a temperature gradient of one degree per unit distance.
Density - (Measured in Kilogram per Cubic Meter) - The Density of a material shows the denseness of that material in a specific given volume. This is taken as mass per unit volume of a given object.
Specific Heat Capacity - (Measured in Joule per Kilogram per K) - Specific Heat Capacity is the heat required to raise the temperature of the unit mass of a given substance by a given amount.
Temperature to Calculate Cooling Rate - (Measured in Kelvin) - Temperature to calculate cooling rate is calculated is the temperature at which the cooling rate is calculated.
Ambient Temperature - (Measured in Kelvin) - Ambient Temperature is the temperature of the surrounding.
STEP 1: Convert Input(s) to Base Unit
Net Heat Supplied per Unit Length: 1000 Joule per Millimeter --> 1000000 Joule per Meter (Check conversion ​here)
Cooling Rate: 13.71 Celsius per Second --> 13.71 Kelvin per Second (Check conversion ​here)
Thermal Conductivity: 10.18 Watt per Meter per K --> 10.18 Watt per Meter per K No Conversion Required
Density: 997 Kilogram per Cubic Meter --> 997 Kilogram per Cubic Meter No Conversion Required
Specific Heat Capacity: 4.184 Kilojoule per Kilogram per K --> 4184 Joule per Kilogram per K (Check conversion ​here)
Temperature to Calculate Cooling Rate: 500 Celsius --> 773.15 Kelvin (Check conversion ​here)
Ambient Temperature: 37 Celsius --> 310.15 Kelvin (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
z = HNet*sqrt(R/(2*pi*k*ρ*Qc*((Tc-ta)^3))) --> 1000000*sqrt(13.71/(2*pi*10.18*997*4184*((773.15-310.15)^3)))
Evaluating ... ...
z = 0.0227530698779838
STEP 3: Convert Result to Output's Unit
0.0227530698779838 Meter -->22.7530698779838 Millimeter (Check conversion ​here)
FINAL ANSWER
22.7530698779838 22.75307 Millimeter <-- Thickness
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rajat Vishwakarma
University Institute of Technology RGPV (UIT - RGPV), Bhopal
Rajat Vishwakarma has created this Calculator and 400+ more calculators!
Verifier Image
Verified by Nishan Poojary
Shri Madhwa Vadiraja Institute of Technology and Management (SMVITM), Udupi
Nishan Poojary has verified this Calculator and 400+ more calculators!

13 Heat Flow in Welded Joints Calculators

Peak Temperature Reached at any Point in Material
​ Go Peak Temperature Reached at a Distance of y = Ambient Temperature+(Net Heat Supplied per Unit Length*(Melting Temperature of Base Metal-Ambient Temperature))/((Melting Temperature of Base Metal-Ambient Temperature)*sqrt(2*pi*e)*Density of Metal*Thickness of the Metal*Specific Heat Capacity*Distance from the Fusion Boundary+Net Heat Supplied per Unit Length)
Position of peak temperature from fusion boundary
​ Go Distance from the Fusion Boundary = ((Melting Temperature of Base Metal-Temperature Reached at a Distance of y)*Net Heat Supplied per Unit Length)/((Temperature Reached at a Distance of y-Ambient Temperature)*(Melting Temperature of Base Metal-Ambient Temperature)*sqrt(2*pi*e)*Density*Specific Heat Capacity*Thickness of the Metal)
Net heat supplied to weld area to raise it to given temperature from fusion boundary
​ Go Net Heat Supplied per Unit Length = ((Temperature Reached at a Distance of y-Ambient Temperature)*(Melting Temperature of Base Metal-Ambient Temperature)*sqrt(2*pi*e)*Density*Specific Heat Capacity*Thickness of the Metal*Distance from the Fusion Boundary)/(Melting Temperature of Base Metal-Temperature Reached at a Distance of y)
Net heat supplied to achieve given cooling rates for thin plates
​ Go Net Heat Supplied per Unit Length = Thickness of the Metal/sqrt(Cooling Rate of Thinplate/(2*pi*Thermal Conductivity*Density*Specific Heat Capacity*((Temperature to Calculate Cooling Rate-Ambient Temperature)^3)))
Thickness of base metal for desired cooling rate
​ Go Thickness = Net Heat Supplied per Unit Length*sqrt(Cooling Rate/(2*pi*Thermal Conductivity*Density*Specific Heat Capacity*((Temperature to Calculate Cooling Rate-Ambient Temperature)^3)))
Thermal conductivity of base metal using given cooling rate (thin plates)
​ Go Thermal Conductivity = Cooling Rate of Thinplate/(2*pi*Density*Specific Heat Capacity*((Thickness of the Metal/Net Heat Supplied per Unit Length)^2)*((Temperature to Calculate Cooling Rate-Ambient Temperature)^3))
Cooling rate for relatively thin plates
​ Go Cooling Rate of Thinplate = 2*pi*Thermal Conductivity*Density*Specific Heat Capacity*((Thickness of the Metal/Net Heat Supplied per Unit Length)^2)*((Temperature to Calculate Cooling Rate-Ambient Temperature)^3)
Relative plate thickness factor
​ Go Relative Plate Thickness Factor = Thickness of the Metal*sqrt(((Temperature to Calculate Cooling Rate-Ambient Temperature)*Density of Metal*Specific Heat Capacity)/Net Heat Supplied per Unit Length)
Thickness of Base Metal using Relative Thickness Factor
​ Go Thickness of the Base Metal = Relative Plate Thickness Factor*sqrt(Net Heat Supplied per Unit Length/((Temperature to Calculate Cooling Rate-Ambient Temperature)*Density*Specific Heat Capacity))
Net Heat supplied using Relative Thickness Factor
​ Go Net Heat Supplied = ((Thickness of the Metal/Relative Plate Thickness Factor)^2)*Density*Specific Heat Capacity*(Temperature to Calculate Cooling Rate-Ambient Temperature)
Thermal conductivity of base metal using given cooling rate (thick plates)
​ Go Thermal Conductivity = (Cooling Rate*Net Heat Supplied per Unit Length)/(2*pi*((Temperature to Calculate Cooling Rate-Ambient Temperature)^2))
Net heat supplied to achieve given cooling rates for thick plates
​ Go Net Heat Supplied per Unit Length = (2*pi*Thermal Conductivity*((Temperature to Calculate Cooling Rate-Ambient Temperature)^2))/Cooling Rate
Cooling Rate for Relatively Thick Plates
​ Go Cooling Rate = (2*pi*Thermal Conductivity*((Temperature to Calculate Cooling Rate-Ambient Temperature)^2))/Net Heat Supplied per Unit Length

Thickness of base metal for desired cooling rate Formula

Thickness = Net Heat Supplied per Unit Length*sqrt(Cooling Rate/(2*pi*Thermal Conductivity*Density*Specific Heat Capacity*((Temperature to Calculate Cooling Rate-Ambient Temperature)^3)))
z = HNet*sqrt(R/(2*pi*k*ρ*Qc*((Tc-ta)^3)))

How heat transfer takes place near heat affected zone ?

Heat transfer in a welded joint is a complex phenomenon involving three dimensional movement of a heat source. Heat from the weld zone is transferred more to the other parts of the base metal by means of conduction. Similarly heat is also lost to surroundings by convection from the surface, with radiation component being relatively small except near the weld pool. Thus the analytical treatment of the weld zone is extremely difficult.

How to Calculate Thickness of base metal for desired cooling rate?

Thickness of base metal for desired cooling rate calculator uses Thickness = Net Heat Supplied per Unit Length*sqrt(Cooling Rate/(2*pi*Thermal Conductivity*Density*Specific Heat Capacity*((Temperature to Calculate Cooling Rate-Ambient Temperature)^3))) to calculate the Thickness, The Thickness of base metal for desired cooling rate formula is defined as the thickness of base metal as required for given cooling rate. Thickness is denoted by z symbol.

How to calculate Thickness of base metal for desired cooling rate using this online calculator? To use this online calculator for Thickness of base metal for desired cooling rate, enter Net Heat Supplied per Unit Length (HNet), Cooling Rate (R), Thermal Conductivity (k), Density (ρ), Specific Heat Capacity (Qc), Temperature to Calculate Cooling Rate (Tc) & Ambient Temperature (ta) and hit the calculate button. Here is how the Thickness of base metal for desired cooling rate calculation can be explained with given input values -> 22753.07 = 1000000*sqrt(13.71/(2*pi*10.18*997*4184*((773.15-310.15)^3))).

FAQ

What is Thickness of base metal for desired cooling rate?
The Thickness of base metal for desired cooling rate formula is defined as the thickness of base metal as required for given cooling rate and is represented as z = HNet*sqrt(R/(2*pi*k*ρ*Qc*((Tc-ta)^3))) or Thickness = Net Heat Supplied per Unit Length*sqrt(Cooling Rate/(2*pi*Thermal Conductivity*Density*Specific Heat Capacity*((Temperature to Calculate Cooling Rate-Ambient Temperature)^3))). Net heat supplied per unit length can also be converted to newton since energy is newton multiplied meter, Cooling Rate is the time rate of decrease of temperature of a particular material, Thermal Conductivity is rate of heat passes through specified material, expressed as amount of heat flows per unit time through a unit area with a temperature gradient of one degree per unit distance, The Density of a material shows the denseness of that material in a specific given volume. This is taken as mass per unit volume of a given object, Specific Heat Capacity is the heat required to raise the temperature of the unit mass of a given substance by a given amount, Temperature to calculate cooling rate is calculated is the temperature at which the cooling rate is calculated & Ambient Temperature is the temperature of the surrounding.
How to calculate Thickness of base metal for desired cooling rate?
The Thickness of base metal for desired cooling rate formula is defined as the thickness of base metal as required for given cooling rate is calculated using Thickness = Net Heat Supplied per Unit Length*sqrt(Cooling Rate/(2*pi*Thermal Conductivity*Density*Specific Heat Capacity*((Temperature to Calculate Cooling Rate-Ambient Temperature)^3))). To calculate Thickness of base metal for desired cooling rate, you need Net Heat Supplied per Unit Length (HNet), Cooling Rate (R), Thermal Conductivity (k), Density (ρ), Specific Heat Capacity (Qc), Temperature to Calculate Cooling Rate (Tc) & Ambient Temperature (ta). With our tool, you need to enter the respective value for Net Heat Supplied per Unit Length, Cooling Rate, Thermal Conductivity, Density, Specific Heat Capacity, Temperature to Calculate Cooling Rate & Ambient Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!