Total Wave Energy given Kinetic Energy and Potential Energy Solution

STEP 0: Pre-Calculation Summary
Formula Used
Total Energy of Wave per Width = Kinetic Energy of Wave per Unit Width+Potential Energy per Unit Width
TE = KE+PE
This formula uses 3 Variables
Variables Used
Total Energy of Wave per Width - (Measured in Joule per Meter) - The total energy of wave per Width is the sum of its kinetic energy and its potential energy.
Kinetic Energy of Wave per Unit Width - (Measured in Joule) - The kinetic energy of wave per Unit Width is the energy associated with the motion of water particles as the wave propagates through a medium.
Potential Energy per Unit Width - (Measured in Joule per Meter) - Potential energy per unit width refers to the amount of potential energy stored per unit distance along the width of a body or structure.
STEP 1: Convert Input(s) to Base Unit
Kinetic Energy of Wave per Unit Width: 10.136 Joule --> 10.136 Joule No Conversion Required
Potential Energy per Unit Width: 10.13 Joule per Meter --> 10.13 Joule per Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
TE = KE+PE --> 10.136+10.13
Evaluating ... ...
TE = 20.266
STEP 3: Convert Result to Output's Unit
20.266 Joule per Meter --> No Conversion Required
FINAL ANSWER
20.266 Joule per Meter <-- Total Energy of Wave per Width
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verifier Image
Verified by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has verified this Calculator and 900+ more calculators!

13 Wave Energy Calculators

Wave Height given Total Wave Energy in one Wavelength per unit Crest Width
​ Go Wave Height = sqrt((8*Total Energy of Wave per Width)/(Density of Fluid*[g]*Wavelength))
Wavelength for total wave energy in wavelength per unit crest width
​ Go Wavelength = (8*Total Energy of Wave per Width)/(Density of Fluid*[g]*Wave Height^2)
Total Wave Energy in one Wavelength per unit Crest Width
​ Go Total Energy of Wave per Width = (Density of Fluid*[g]*Wave Height^2*Wavelength)/8
Total Wave Energy given Kinetic Energy and Potential Energy
​ Go Total Energy of Wave per Width = Kinetic Energy of Wave per Unit Width+Potential Energy per Unit Width
Potential Energy given Total Wave Energy
​ Go Potential Energy per Unit Width = Total Energy of Wave per Width-Kinetic Energy of Wave per Unit Width
Specific Energy or Energy Density in terms Wave Height
​ Go Energy Density of Wave = (Density of Fluid*[g]*Wave Height^2)/8
Total Wave Energy given Wave Power for Shallow Water
​ Go Total Wave Energy = Wave Power for Shallow Depth/Celerity for Shallow Depth
Wave Celerity given Wave Power for Shallow Water
​ Go Celerity for Shallow Depth = Wave Power for Shallow Depth/Total Wave Energy
Deepwater Celerity for Wave Power of Deepwater
​ Go Deepwater Wave Celerity = Wave Power for Deep Water/(0.5*Total Wave Energy)
Total Wave Energy for Wave Power of Deepwater
​ Go Total Wave Energy = Wave Power for Deep Water/(0.5*Deepwater Wave Celerity)
Wave Power for Shallow Water
​ Go Wave Power for Shallow Depth = Total Wave Energy*Celerity for Shallow Depth
Wave Power for Deepwater
​ Go Wave Power for Deep Water = 0.5*Total Wave Energy*Deepwater Wave Celerity
Specific energy or energy density given wavelength and wave energy
​ Go Energy Density of Wave = Total Energy of Wave per Width/Wavelength

Total Wave Energy given Kinetic Energy and Potential Energy Formula

Total Energy of Wave per Width = Kinetic Energy of Wave per Unit Width+Potential Energy per Unit Width
TE = KE+PE

What type of energy is wave energy?

Wave Energy is an indirect form of wind energy that causes movement of the water on the surface of the oceans and by capturing this energy the motion of the waves is converted to mechanical energy and used to drive an electricity generator.

How to Calculate Total Wave Energy given Kinetic Energy and Potential Energy?

Total Wave Energy given Kinetic Energy and Potential Energy calculator uses Total Energy of Wave per Width = Kinetic Energy of Wave per Unit Width+Potential Energy per Unit Width to calculate the Total Energy of Wave per Width, The Total Wave Energy given Kinetic Energy and Potential Energy is the transport and capture of energy by ocean surface waves. The energy captured is then used for all different kinds of useful work, including electricity generation, water desalination, and pumping of water. Total Energy of Wave per Width is denoted by TE symbol.

How to calculate Total Wave Energy given Kinetic Energy and Potential Energy using this online calculator? To use this online calculator for Total Wave Energy given Kinetic Energy and Potential Energy, enter Kinetic Energy of Wave per Unit Width (KE) & Potential Energy per Unit Width (PE) and hit the calculate button. Here is how the Total Wave Energy given Kinetic Energy and Potential Energy calculation can be explained with given input values -> 20.266 = 10.136+10.13.

FAQ

What is Total Wave Energy given Kinetic Energy and Potential Energy?
The Total Wave Energy given Kinetic Energy and Potential Energy is the transport and capture of energy by ocean surface waves. The energy captured is then used for all different kinds of useful work, including electricity generation, water desalination, and pumping of water and is represented as TE = KE+PE or Total Energy of Wave per Width = Kinetic Energy of Wave per Unit Width+Potential Energy per Unit Width. The kinetic energy of wave per Unit Width is the energy associated with the motion of water particles as the wave propagates through a medium & Potential energy per unit width refers to the amount of potential energy stored per unit distance along the width of a body or structure.
How to calculate Total Wave Energy given Kinetic Energy and Potential Energy?
The Total Wave Energy given Kinetic Energy and Potential Energy is the transport and capture of energy by ocean surface waves. The energy captured is then used for all different kinds of useful work, including electricity generation, water desalination, and pumping of water is calculated using Total Energy of Wave per Width = Kinetic Energy of Wave per Unit Width+Potential Energy per Unit Width. To calculate Total Wave Energy given Kinetic Energy and Potential Energy, you need Kinetic Energy of Wave per Unit Width (KE) & Potential Energy per Unit Width (PE). With our tool, you need to enter the respective value for Kinetic Energy of Wave per Unit Width & Potential Energy per Unit Width and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Total Energy of Wave per Width?
In this formula, Total Energy of Wave per Width uses Kinetic Energy of Wave per Unit Width & Potential Energy per Unit Width. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Total Energy of Wave per Width = (Density of Fluid*[g]*Wave Height^2*Wavelength)/8
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!