How to Calculate Two parallel Isothermal Cylinders placed in Infinite medium?
Two parallel Isothermal Cylinders placed in Infinite medium calculator uses Conduction Shape Factor = (2*pi*Length of Cylinder)/acosh((4*Distance Between Centers^2-Diameter of Cylinder 1^2-Diameter of Cylinder 2^2)/(2*Diameter of Cylinder 1*Diameter of Cylinder 2)) to calculate the Conduction Shape Factor, Two parallel Isothermal Cylinders placed in Infinite medium formula give the shape factor when two parallel cylinders at some distance are placed in an infinite medium for heat conduction. Conduction Shape Factor is denoted by S symbol.
How to calculate Two parallel Isothermal Cylinders placed in Infinite medium using this online calculator? To use this online calculator for Two parallel Isothermal Cylinders placed in Infinite medium, enter Length of Cylinder (Lc), Distance Between Centers (d), Diameter of Cylinder 1 (D1) & Diameter of Cylinder 2 (D2) and hit the calculate button. Here is how the Two parallel Isothermal Cylinders placed in Infinite medium calculation can be explained with given input values -> 28.00001 = (2*pi*4)/acosh((4*10.1890145^2-5.1^2-13.739222^2)/(2*5.1*13.739222)).