How to Calculate Effective Column Length given Allowable Axial Compression Stress, SL Ratio Greater than 160?
Effective Column Length given Allowable Axial Compression Stress, SL Ratio Greater than 160 calculator uses Effective Column Length = 1.2-(Allowable compression stress/Value obtained from Secant Formula)*(800*Least Radius of Gyration Column) to calculate the Effective Column Length, Effective column length given allowable axial compression stress, SL ratio greater than 160 formula is the distance between successive inflection points or points of zero moments. Effective Column Length is denoted by Leff symbol.
How to calculate Effective Column Length given Allowable Axial Compression Stress, SL Ratio Greater than 160 using this online calculator? To use this online calculator for Effective Column Length given Allowable Axial Compression Stress, SL Ratio Greater than 160, enter Allowable compression stress (Fa), Value obtained from Secant Formula (σc') & Least Radius of Gyration Column (rleast) and hit the calculate button. Here is how the Effective Column Length given Allowable Axial Compression Stress, SL Ratio Greater than 160 calculation can be explained with given input values -> 260187.4 = 1.2-(10000000/400250000)*(800*0.04702).