Width of I Cross Section of Connecting Rod Solution

STEP 0: Pre-Calculation Summary
Formula Used
Width of Connecting Rod = 4*Thickness of Flange And Web of I Section
w = 4*t
This formula uses 2 Variables
Variables Used
Width of Connecting Rod - (Measured in Meter) - Width of Connecting Rod defines the geometric measurement or extent of the connecting rod cross section from side to side.
Thickness of Flange And Web of I Section - (Measured in Meter) - Thickness of flange and web of I section is the thickness of horizontal and vertical parts of an I section beam or a bar.
STEP 1: Convert Input(s) to Base Unit
Thickness of Flange And Web of I Section: 8 Millimeter --> 0.008 Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
w = 4*t --> 4*0.008
Evaluating ... ...
w = 0.032
STEP 3: Convert Result to Output's Unit
0.032 Meter -->32 Millimeter (Check conversion ​here)
FINAL ANSWER
32 Millimeter <-- Width of Connecting Rod
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Saurabh Patil
Shri Govindram Seksaria Institute of Technology and Science (SGSITS ), Indore
Saurabh Patil has created this Calculator and 700+ more calculators!
Verifier Image
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

11 Buckling in Connecting Rod Calculators

Critical Buckling Load on Connecting Rod by Rankine Formula
​ Go Critical Buckling Load on Connecting Rod = Compressive Yield Stress*Cross Sectional Area of Connecting Rod/(1+Constant Used in Buckling Load Formula*(Length of the Connecting Rod/Radius of Gyration of I Section About XX Axis)^2)
Whipping Stress in Connecting Rod of I Cross Section
​ Go Whipping Stress = Mass of Connecting Rod*Angular Velocity of Crank^2*Crank Radius of Engine*Length of the Connecting Rod*4.593/(1000*Thickness of Flange And Web of I Section^3)
Critical Buckling Load on Steel Connecting Rod given Thickness of Flange or Web of Connecting Rod
​ Go Critical Buckling Load on Steel Connecting Rod = (261393*Compressive Yield Stress*Thickness of Flange And Web of I Section^4)/(23763*Thickness of Flange And Web of I Section^2+Length of the Connecting Rod)
Maximum Force Acting on Connecting Rod given Maximum Gas Pressure
​ Go Force on Connecting Rod = pi*Inner Diameter of Engine Cylinder^2*Maximum Pressure in Engine Cylinder/4
Force Acting on Connecting Rod
​ Go Force on Connecting Rod = Force on Piston Head/cos(Inclination of Connecting Rod With Line of Stroke)
Area Moment of Inertia for Connecting Rod Cross Section
​ Go Area Moment of Inertia For Connecting Rod = Cross Sectional Area of Connecting Rod*Radius of Gyration For Connecting Rod^2
Critical Buckling Load on Connecting Rod Considering Factor of Safety
​ Go Critical Buckling Load on Connecting Rod = Force on Connecting Rod*Factor of Safety For Connecting Rod
Radius of Gyration of I Cross Section about yy Axis
​ Go Radius of Gyration of I Section About YY Axis = 0.996*Thickness of Flange And Web of I Section
Radius of Gyration of I Cross Section about xx Axis
​ Go Radius of Gyration of I Section About XX Axis = 1.78*Thickness of Flange And Web of I Section
Height of Cross Section of Connecting Rod at Middle Section
​ Go Height of Connecting Rod at Mid Section = 5*Thickness of Flange And Web of I Section
Width of I Cross Section of Connecting Rod
​ Go Width of Connecting Rod = 4*Thickness of Flange And Web of I Section

Width of I Cross Section of Connecting Rod Formula

Width of Connecting Rod = 4*Thickness of Flange And Web of I Section
w = 4*t

Benefits of I section for connecting rod

Reducing the weight of connecting rod without compensating the strength of the connecting rod, the connecting rod of the engine is of I-section. The I-section has greater strength than the round section without compensating its strength.
The most suitable cross-section in a beam is the I Section since it offers more moment of inertia about the x-x axis with less cross-section area. I-section in comparison to any other provides a higher section modulus and thus provides better lateral stability as compared to other sections.

How to Calculate Width of I Cross Section of Connecting Rod?

Width of I Cross Section of Connecting Rod calculator uses Width of Connecting Rod = 4*Thickness of Flange And Web of I Section to calculate the Width of Connecting Rod, Width of I cross section of connecting rod is the measurement or extent of I cross sectioned connecting rod from side to side. Width of Connecting Rod is denoted by w symbol.

How to calculate Width of I Cross Section of Connecting Rod using this online calculator? To use this online calculator for Width of I Cross Section of Connecting Rod, enter Thickness of Flange And Web of I Section (t) and hit the calculate button. Here is how the Width of I Cross Section of Connecting Rod calculation can be explained with given input values -> 32000 = 4*0.008.

FAQ

What is Width of I Cross Section of Connecting Rod?
Width of I cross section of connecting rod is the measurement or extent of I cross sectioned connecting rod from side to side and is represented as w = 4*t or Width of Connecting Rod = 4*Thickness of Flange And Web of I Section. Thickness of flange and web of I section is the thickness of horizontal and vertical parts of an I section beam or a bar.
How to calculate Width of I Cross Section of Connecting Rod?
Width of I cross section of connecting rod is the measurement or extent of I cross sectioned connecting rod from side to side is calculated using Width of Connecting Rod = 4*Thickness of Flange And Web of I Section. To calculate Width of I Cross Section of Connecting Rod, you need Thickness of Flange And Web of I Section (t). With our tool, you need to enter the respective value for Thickness of Flange And Web of I Section and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!