y11 Parameter Using h22 Parameter Solution

STEP 0: Pre-Calculation Summary
Formula Used
y11_parameter = Delta-Y/H22 Parameter
Y11 = Δy/H22
This formula uses 2 Variables
Variables Used
Delta-Y- Delta-Y is defined as the delta impedance of Y.
H22 Parameter - H22 Parameter is open circuit output admittance. (Measured in Mho)
STEP 1: Convert Input(s) to Base Unit
Delta-Y: 6 --> No Conversion Required
H22 Parameter: 2.22 Mho --> 2.22 Siemens (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Y11 = Δy/H22 --> 6/2.22
Evaluating ... ...
Y11 = 2.7027027027027
STEP 3: Convert Result to Output's Unit
2.7027027027027 Siemens -->2.7027027027027 Mho (Check conversion here)
FINAL ANSWER
2.7027027027027 Mho <-- Y11 Parameter
(Calculation completed in 00.016 seconds)

10+ Different Parameters Using h Parameters Calculators

z22 Parameter Using h21 Parameter
z22_parameter = (-1)*Z21 Parameter/H21 Parameter Go
z22 Parameter Using h12 Parameter
z22_parameter = Z12 Parameter/H12 Parameter Go
y11 Parameter Using h21 Parameter
y11_parameter = Y21 Parameter/H21 Parameter Go
y11 Parameter Using h12 Parameter
y11_parameter = Y21 Parameter/H21 Parameter Go
D Parameter Using h11 Parameter
d_parameter = B parameter/H11 Parameter Go
z22 Parameter Using h11 Parameter
z22_parameter = Delta-Z/H11 Parameter Go
y11 Parameter Using h22 Parameter
y11_parameter = Delta-Y/H22 Parameter Go
D Parameter Using h12 Parameter
d_parameter = Delta-T/H12 Parameter Go
z22 Parameter Using h22 Parameter
z22_parameter = 1/H22 Parameter Go
y11 Parameter Using h11 Parameter
y11_parameter = 1/H11 Parameter Go

y11 Parameter Using h22 Parameter Formula

y11_parameter = Delta-Y/H22 Parameter
Y11 = Δy/H22

What are hybrid parameters?

Hybrid parameters (also known as h parameters) are known as 'hybrid' parameters as they use Z parameters, Y parameters, voltage ratio, and current ratios to represent the relationship between voltage and current in a two-port network.

How to Calculate y11 Parameter Using h22 Parameter?

y11 Parameter Using h22 Parameter calculator uses y11_parameter = Delta-Y/H22 Parameter to calculate the Y11 Parameter, The y11 Parameter Using h22 Parameter formula is defined as driving point Admittance at the port-1 of the short circuit admittance parameters. Y11 Parameter and is denoted by Y11 symbol.

How to calculate y11 Parameter Using h22 Parameter using this online calculator? To use this online calculator for y11 Parameter Using h22 Parameter, enter Delta-Y (Δy) and H22 Parameter (H22) and hit the calculate button. Here is how the y11 Parameter Using h22 Parameter calculation can be explained with given input values -> 2.702703 = 6/2.22.

FAQ

What is y11 Parameter Using h22 Parameter?
The y11 Parameter Using h22 Parameter formula is defined as driving point Admittance at the port-1 of the short circuit admittance parameters and is represented as Y11 = Δy/H22 or y11_parameter = Delta-Y/H22 Parameter. Delta-Y is defined as the delta impedance of Y and H22 Parameter is open circuit output admittance.
How to calculate y11 Parameter Using h22 Parameter?
The y11 Parameter Using h22 Parameter formula is defined as driving point Admittance at the port-1 of the short circuit admittance parameters is calculated using y11_parameter = Delta-Y/H22 Parameter. To calculate y11 Parameter Using h22 Parameter, you need Delta-Y (Δy) and H22 Parameter (H22). With our tool, you need to enter the respective value for Delta-Y and H22 Parameter and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Y11 Parameter?
In this formula, Y11 Parameter uses Delta-Y and H22 Parameter. We can use 10 other way(s) to calculate the same, which is/are as follows -
  • z22_parameter = Delta-Z/H11 Parameter
  • z22_parameter = Z12 Parameter/H12 Parameter
  • z22_parameter = 1/H22 Parameter
  • z22_parameter = (-1)*Z21 Parameter/H21 Parameter
  • y11_parameter = Y21 Parameter/H21 Parameter
  • y11_parameter = Delta-Y/H22 Parameter
  • y11_parameter = Y21 Parameter/H21 Parameter
  • y11_parameter = 1/H11 Parameter
  • d_parameter = B parameter/H11 Parameter
  • d_parameter = Delta-T/H12 Parameter
Where is the y11 Parameter Using h22 Parameter calculator used?
Among many, y11 Parameter Using h22 Parameter calculator is widely used in real life applications like {FormulaUses}. Here are few more real life examples -